Please Read This First!

If you read nothing else in these instructions, please at least take a moment to read the following and pay special attention to the bolded items:

  1. Do not use blue fast-setting glue. It’s extremely aggressive and can damage the ABS plastic used in the construction of the valve housing.
  2. Place the coupling nut on the pipe before gluing the coupling. This is a common mistake that is easily avoided.
  3. When changing cams, make sure that the two o-rings are in place. Cams are installed with the numbers facing up, and inactive outlets have no corresponding number.
  4. Make certain the proper cam for the number of zones is being used. We recommend capping off unused outlets 6–8″ below the valve bottom.
  5. Use standard clear PVC cement and allow it to fully cure! We can’t stress this enough, as many valves are returned with blown-out pipes. Consult the label on the container of PVC cement for the full cure time.
  6. Do not use cleaner or purple primer on the indexing valve. It’s unnecessary and can damage the housing.

We are a small American manufacturer, owned and operated by the same family for more than 60 years now. All of our valves are completely molded and assembled in Jupiter, Florida. Around 80% of the products returned to us have parts stolen or blown-out pipes, meaning we lose thousands of dollars each year due to theft and avoidable returns.

If you purchase a product with missing pieces, let us know. If you only need one specific part, please don’t purchase the entire valve and cannibalize it before returning it to the store. We sell all of the individual parts on the website. Above all else, let the PVC cement fully cure before pressurizing the valve!

Indexing Valve Series

1000 Series ¬
The 1000 series is 1″ in and 1″ out, made of ABS plastic, and comes in 4, 6, and 8-outlet models. The 1000 series is considered one of our two ‘mini’ valves, with six screws around the perimeter.

2000 Series ¬
The 2000 series is 1.5″ in and 1.25″ out, made of ABS plastic, and comes in 4 and 6-outlet models. The 2000 series is considered one of our two ‘mini’ valves, with six screws around the perimeter.

3000 Series ¬
The 3000 series is 1.5″ in and 1.25″ out, made of ABS plastic, and comes in 4 and 6-outlet models. The 3000–6000 series are our ‘standard size’ valves, with eight screws around the perimeter.

4000 Series ¬
The 4000 series is 1.5″ in and 1.25″ out, made of ABS plastic, and comes in 4 and 6-outlet models. The 3000–6000 series are our ‘standard size’ valves, with eight screws around the perimeter.

5000 Series ¬
The 5000 series is 1.5″ in and 1.25″ out, made of ABS plastic, and comes in 4 and 6-outlet models. The material used in the construction of the top of this unit is more industrial strength. They are generally utilized in higher pressure/flow situations.

6000 Series ¬
The 6000 series is 1.5″ in and 1.25″ out, made of ABS plastic, and comes in 4 and 6-outlet models. The material used in the construction of the top of this unit is more industrial strength. They are generally utilized in higher pressure/flow situations.

Valve SeriesPump HPMeter SizeFlow Rate
10003/4-15/8″-1″10-24 GPM
20003/4-15/8″-1″10-30 GPM
30001 1/21″-1 1/2″10-50 GPM
40001 1/2 – 21″-1 1/2″10-75 GPM
50001 1/2 – 31″-1 1/2″10-100 GPM
60001 1/2 – 31″-1 1/2″10-100 GPM

Cam Configuration / Outlet Diagram

The Hydro-Indexing Valve can be configured to run a different number of zones by swapping the cam on top of the valve with the proper zone cam. Each cam has numbers on top, and each number corresponds with an active outlet.

EXAMPLE: A 3-zone cam would have a 1, 2, and 3 on top of the cam. A 6 would have 1, 2, 3, 4, 5, and 6. The 7 and 8-zone cams are not numbered on the cam but on the valve body itself.

Always use the outlet that is directly below a number on the cam. If there is no number on the cam, that corresponding outlet is inactive.

The numbered circles indicate active outlets for the cam being used. If there is no number then that corresponding outlet is inactive.

Changing Cams

Remove the four screws on the cam cover and lift it off. There is one slot that goes all the way through the cam, line up the top tab on the stem with that slot and remove the cam.

If the new cam doesn’t have the two o-rings, remove them from the old cam and place them on the new one. Make certain that the numbers are facing up when you install the new cam.

Slide the cam down over the stem the same way you removed it and line up the notch in the cam with the locator pin on top of the valve. Replace the cam cover and retighten the screws. Pipe up to the outlets that are directly below the numbers on the cam.

CAUTION: WHEN REPLACING THE CAM ON THE VALVE MAKE SURE THE NUMBERS ON THE TOP SIDE OF THE CAM ARE FACING AND THE O-RINGS ARE IN PLACE ON BOTH SIDES OF THE CAM!

Valve Installation Instructions

1) Increase the pipe to a minimum of one size larger (min. 1″) immediately after the water meter and use no smaller than a 1″ solenoid valve on city water systems.

2) All lines to the valve should be flushed out to clear debris before installing the valve.

3) IMPORTANT: PLACE COUPLING NUT ON COUPLING BEFORE GLUING!

4) On plastic valves, apply standard clear PVC cement to the outside of the pipe, do not use blue fast-setting glue. If you choose to apply PVC cement to the inside of the valve outlets, be careful not to get any inside of the housing. Insert the pipe into the outlet and hold for approximately 30 seconds to a minute to keep the pipe from sliding back out. For a better hold, twist the pipe 1/4 turn while inserting it into the outlet. Do not hold the valve upside down while applying the cement to prevent getting any inside of the housing. Ensure all connections reach full cure time before submitting the valve to internal water pressure. For most brands, this is a minimum of 2 hours. Consult the can of PVC cement for specific cure times.

5) Hand-tighten the coupling nut to the threaded valve top.

6) On runs longer than 150 feet, the pipe should be at least 1.25″.

7) The valve should be installed higher than the sprinklers and lines.

8) On unused outlets, glue an 8-10″ pipe into the inactive outlet and cap it off. You may add zones to the system later by connecting the pipe or pipes to the system and changing the cam.

9) Ensure the proper cam is used and the two cam o-rings are in place.

City Water Installation

For city water installations, no less than a 1″ solenoid and 1″ pipe leading into the valve should be used. A gate or ball valve can be used for manual operation. For automatic operation, an electric solenoid and an electric timer must be installed.

A typical city water installation consists of the water supply line from the meter, a single inline solenoid/anti-siphon valve, and a controller to dictate start/run times.

Pump Installation

On a pump installation, the valve can be operated manually by a switch connected to the pump or automatically operated by connecting an electronic controller to the pump. A working check valve on the suction side is critical to proper valve function. The valve can be installed directly off the discharge side of the pump. We recommend installing a hose bib on the discharge side of the pump to aid in priming.

Pump installations vary greatly. In the most basic sense, a primed pump is needed along with a controller to turn it on and off. We recommend installing a ball valve on the distribution side of the pump.

The Zone Indicator (Optional)

The knob on top of the cam has an arrow that points to the active zone. When the pump is turned off, index the valve to the desired zone by pushing and releasing the zone indicator. When the pump is turned back on, the system will automatically start on that zone. This optional item for the hydro-indexing valve is great to use when working on sprinkler heads.

Zone Indicator Installation

  1. Remove the four cam screws and remove the cam cover. Make sure that the o-ring on top of the cam remains in place.
  2. Rest the zone indicator on top of the stem, there is a keyway that needs to be aligned.
  3. Rotate the arrowed knob until it slides freely (do not force it) into the hole in the top of the stem.
  4. Retighten the screws

FIMCO Valve Parts Diagram

  1. Cam Cover
  2. Cam Screws
  3. Cam O-rings
  4. Cam
  5. Valve Top Screws
  6. Valve Top
  7. Valve Top O-ring
  8. Flow Cup
  9. Disk
  10. Stem
  11. Valve Bottom
  12. Coupling O-ring
  13. Coupling
  14. Coupling Nut
  15. Optional Zone Indicator

Basic Troubleshooting Guide

Water comes out of more than one zone at a time.

Something is keeping the disk from seating properly. This is likely a lack of water volume, but it could also be an obstruction inside the valve housing. Out of the box, a minimum of 10 gallons per minute is required for proper valve function. Keep in mind this means 10 gallons flow through the unit. If you have 1 or 2 heads on a specific zone, the volume flowing through the unit will be reduced, as the heads can only allow so much flow. Systems running on lower than 10 GPM may require our low-flow stem and disk assembly, which will run on as little as 6 GPM.

The valve fails to index

  1. Remove the four screws on top of the valve and remove the cam cover. Hold the cam in place as if it’s still fastened by the screws. With your other hand, press and release the stem 10-12 times to test for proper function. Should the stem fail to rotate, check the two tabs above and below the cam to ensure they aren’t damaged.
  2. If you have an artesian (free-flowing) well, you must place a synchronized electric or hydraulic valve between the pump and the valve. The electric valve or hydraulic MUST be synchronized with the pump to come on automatically. This will completely cease the flow of water and allow proper function.

The valve skips zones

  1. Check to make sure the correct cam is used with regard to any capped-off/unused outlets.
  2. Clean the check valve or install a new one, as a faulty check valve will cause the indexing valve to jump.
  3. Any zone higher in elevation than the valve could create a backflow. Plumb a check valve at the lowest point of the incline nearest the valve or raise the valve higher than the sprinkler lines.

If you are experiencing problems with the valve other than those listed above, please get in touch with the manufacturer at (561) 624-3308 or by email at info@fimcomfg.com.

Helpful Videos

The Basic Mechanical Test

Changing Stem & Disk Assemblies

Changing Valve Tops

Changing O-rings

Rotating the Cam

Why rotate the cam?

  1. You used to have a different valve, which was plumbed opposite of ours. You need to make zone 2 skip and zone 4 active.
  2. This test only works on installations that use all available outlets. If you have one specific zone that acts up, you can rotate the cam and see if the problem follows the cam. If it’s a mechanical issue, you will see a different zone acting up (the opposite side), and the issue will most likely be resolved with replacement parts. If the problem remains in the same zone, we will need to dive deeper into that specific zone. Please contact us if you get stumped, we’re more than happy to help.

Finding Old Threads

Why back the screws up?

Every time you remove and replace screws in plastic they cut new threads. By utilizing the above method you can add years to the life of plastic products, specifically those that are under considerable water pressure.

Warranty

All FIMCO Hydro-Indexing Valves are guaranteed against faulty materials or workmanship for one year from installation. Any part returned to us within this warranty period showing defects in material or workmanship will be renewed or replaced FOB factory without charge. The liability of the company is limited to the renewal or replacement of the defective parts.

Another Fine FIMCO Product: Snap-on Saddles

Snap-on saddles are an easy way to add sprinklers to a new or existing irrigation system. There is no need to cut pipes and add T fittings. Apply standard clear PVC cement to the saddle and snap it onto the pipe. When fully cured, drill a 1/4″ hole through the 1/2″ threaded connection and into the pipe. The saddle can be used to add sprinkler heads or adapters for 1/2″ to 1.5″ pipe. Snap-on saddles are available in 1/2″, 3/4″, 1″, 1 1/4″, and 1 1/2″.